Generating Automatic & Diagnostic System
제품소개영문
It stores power generated from renewable energy sources such as solar and wind and maximizes the function of the passive cooling system with energy storage that supplies power to consumers and transmits it to the electric system if necessary, allowing completely sealed cooling with ultra-low power compared to existing air conditioners. |
Content | Spec. |
Round Trip Efficiency | - 80% PCS rated [battery Effciency 90%] |
The temperature of the user. | - -20℃ ~ +40℃ |
Sealed level. | - IP65 |
PMS | - Protocol : DNP, Modbus, IEC61850(Server) (Option) - Communication Port 1) Ethernet : 3 Port (100BASE-T 3 Port) 100BASE-F (Multi) 1 Poert Optino 2) RS-232C / RF-485 : 2 Port 3) Wireless Communication (Option) : LTE, GSM - I/O Port : 12 DI / 400 / 4AI - Operation Temperature : -20℃ ~ +65℃ |
PCS | - Rated output voltage : 100kW: 3phase, 380V [+10°C / -10%] - Cooling method : Natural air conditioning type, forced air cooling type - Communication with high-level devices : RS-485 Modbus - Certificate : SPS-SGSF-025-4-1972 Standard testing institution certification |
Battery | - Operable Capacity : 278kWh - Battery type: Lithium series - Cycle life : 4,000cycle, 25±5℃ - Cooling Method : Intelligent SuperPower Saving Air Conditioning System |